1.
BMC Oral Health ; 24(1): 455, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622680

ABSTRACT

BACKGROUND: The aim of this study is to evaluate the biomechanical behavior of the mesial and distal off-axial extensions of implant-retained prostheses in the posterior maxilla with different prosthetic materials using finite element analysis (FEA). METHODS: Three dimensional (3D) finite element models with three implant configurations and prosthetic designs (fixed-fixed, mesial cantilever, and distal cantilever) were designed and modelled depending upon cone beam computed tomography (CBCT) images of an intact maxilla of an anonymous patient. Implant prostheses with two materials; Monolithic zirconia (Zr) and polyetherketoneketone (PEKK) were also modeled .The 3D modeling software Mimics Innovation Suite (Mimics 14.0 / 3-matic 7.01; Materialise, Leuven, Belgium) was used. All the models were imported into the FE package Marc/Mentat (ver. 2015; MSC Software, Los Angeles, Calif). Then, individual models were subjected to separate axial loads of 300 N. Von mises stress values were computed for the prostheses, implants, and bone under axial loading. RESULTS: The highest von Mises stresses in implant (111.6 MPa) and bone (100.0 MPa) were recorded in distal cantilever model with PEKK material, while the lowest values in implant (48.9 MPa) and bone (19.6 MPa) were displayed in fixed fixed model with zirconia material. The distal cantilever model with zirconia material yielded the most elevated levels of von Mises stresses within the prosthesis (105 MPa), while the least stresses in prosthesis (35.4 MPa) were recorded in fixed fixed models with PEKK material. CONCLUSIONS: In the light of this study, the combination of fixed fixed implant prosthesis without cantilever using a rigid zirconia material exhibits better biomechanical behavior and stress distribution around bone and implants. As a prosthetic material, low elastic modulus PEKK transmitted more stress to implants and surrounding bone especially with distal cantilever.


Subject(s)
Dental Implants , Zirconium , Humans , Finite Element Analysis , Maxilla/surgery , Dental Prosthesis, Implant-Supported , Dental Stress Analysis/methods , Stress, Mechanical
2.
J Oral Implantol ; 50(1): 9-17, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38579116

ABSTRACT

The goal of this clinical report was to present an alternative to traditional flat bone reduction guides, using a custom-designed 3-dimensional (3D)-printed guide according to the future gingival margin of the planned dentition. A 61-year-old woman with concerns regarding her smile appearance was presented. The initial examination revealed excessive gingival show accompanied by excessive overjet. The dentition was in a failing situation. The proposed treatment plan, relying on the sufficient amount of bone and keratinized tissue, consisted of recontouring of the alveolar ridge and gingiva and placement of 6 implants and an FP-1 prosthesis after extraction of all remaining maxillary teeth. Digital smile design was completed, and a fully digitally guided surgery was planned. This consisted of using 3 surgical guides, starting with the fixation pin guide, continuing with the scalloped hard- and soft-tissue reduction guide, and finally the implant placement template. Following the surgery, the patient received a temporary restoration, and on the 4-month follow-up, a new polymethyl meta-acrylate temporary prosthesis was delivered. The patient's 7-month follow-up is presented in the article. The report of this triple-template guided surgery indicated that digital 3D planning is a considerably predictable tool to properly establish and evaluate future occlusal plane, smile line, and lip support. Scalloped guides seem to be an excellent alternative to conventional bone reduction guides since they require less bone removal and improve patient comfort during surgery.


Subject(s)
Dental Implantation, Endosseous , Dental Implants , Humans , Female , Middle Aged , Dental Implantation, Endosseous/methods , Alveolar Process , Gingiva/surgery , Prosthesis Implantation , Dental Prosthesis, Implant-Supported
3.
BMC Oral Health ; 24(1): 410, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38566034

ABSTRACT

BACKGROUND: To clinically compare the effect of the conventional and the digital workflows on the passive fit of a screw retained bar splinting two inter-foraminal implants. METHODS: The current study was designed to be a parallel triple blinded randomised clinical trial. Thirty six completely edentulous patients were selected and simply randomized into two groups; conventional group (CG) and digital group (DG). The participants, investigator and outcome assessor were blinded. In the group (CG), the bar was constructed following a conventional workflow in which an open top splinted impression and a lost wax casting technology were used. However, in group (DG), a digital workflow including a digital impression and a digital bar milling technology was adopted. Passive fit of each bar was then evaluated clinically by applying the screw resistance test using the "flag" technique in the passive and non passive situations. The screw resistance test parameter was also calculated. Unpaired t-test was used for intergroup comparison. P-value < 0.05 was the statistical significance level. The study protocol was reviewed by the Research Ethics Committee in the author's university (Rec IM051811). Registration of the clinical trial was made on clinical trials.gov ID NCT05770011. An informed consent was obtained from all participants. RESULTS: Non statistically significant difference was denoted between both groups in all situations. In the passive situation, the mean ± standard deviation values were 1789.8° ± 20.7 and1786.1° ± 30.7 for the groups (CG) and (DG) respectively. In the non passive situation, they were 1572.8° ± 54.2 and 1609.2° ± 96.9. Regarding the screw resistance test parameter, they were 217° ± 55.3 and 176° ± 98.8. CONCLUSION: Conventional and digital fabrication workflows had clinically comparable effect on the passive fit of screw retained bar attachments supported by two dental implants.


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Workflow , Dental Impression Technique , Bone Screws , Computer-Aided Design , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis Design
4.
Int J Oral Maxillofac Implants ; 39(2): 278-285, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38657220

ABSTRACT

PURPOSE: To evaluate and compare the difference in retention between implant-supported restorations with and without surface modification of the implant abutments. MATERIALS AND METHODS: A total of 30 patients with singletooth implants were restored with cement-retained (Multilink N, Ivoclar) restorations using titanium base abutments (Variobase, Straumann) and randomly assigned surface modifications. Group 1 used nonmodified abutments, group 2 used sandblasted abutments, and group 3 used sandblasted abutments followed by an application of metal primer. All patients were recalled for a baseline examination 6 months after crown placement. The pull-out strength and intergroup distribution of mean pull-out strength were assessed. To assess differences between the three groups, intergroup statistical comparison of continuous variables was done using one-way ANOVA with Tukey correction for multiple group comparisons. RESULTS: The results of the intergroup mean pull-out strength distribution revealed that the distribution of mean ± SD pull-out strength in group 1, group 2, and group 3 were 220.79 ± 94.23, 488.64 ± 84.12, and 705.46 ± 112.75 Ncm, respectively. CONCLUSIONS: Sandblasting followed by the application of metal primer produced the highest retention of porcelain-fused-to-metal (PFM) crowns to titanium base abutments, followed by sandblasting alone, with the least retention being observed with no surface treatment.


Subject(s)
Dental Abutments , Dental Implant-Abutment Design , Dental Prosthesis Retention , Dental Prosthesis, Implant-Supported , Methacrylates , Surface Properties , Titanium , Humans , Female , Male , Titanium/chemistry , Middle Aged , Crowns , Adult , Dental Stress Analysis
5.
Int J Oral Maxillofac Implants ; 39(2): 294-301, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38657221

ABSTRACT

PURPOSE: To evaluate peri-implant tissue health and bone resorption in patients with implant-supported fixed partial rehabilitations. In particular, possible correlations between plaque accumulation and bone loss, as well as other periimplant health parameters, were investigated. MATERIALS AND METHODS: A total of 44 patients rehabilitated with fixed implant-supported partial rehabilitations were included. The following parameters were recorded: spontaneous bleeding (SB), suppuration, bleeding on probing (BOP), plaque index (PI), and probing depth (PD). Periapical radiographs were taken to measure crestal bone loss (BL). A nonparametric test (Spearman rank coefficient; rs) was used to identify possible correlations between the clinical parameters recorded. RESULTS: A total of 121 implants were analyzed. Global PI and BOP were 49.58% and 20.25%, respectively. There were no cases of suppuration, and only 2 implants showed spontaneous bleeding. Mean BL was 1.53 mm (SD: 0.98). No implants showed peri-implantitis. There was a weak, statistically significant correlation between PI and BL (rs = 0.27, P [2-tailed] = .99) and between PI and the other peri-implant parameters (BOP: rs = 0.14, P = .14; PD: rs = 0.04, P = .65; SB: rs = -0.08, P = .34). A very weak correlation was also found between BL and BOP (rs = 0.1, P = .2) and between BL and PD (rs = 0.02, P = .7). Correlation was found between BL and age (rs = 0.13, P = .81) and between the other peri-implant parameters and age using dichotomization (> or < 65 years; PI: rs = -0.14, P = .11; PD: rs = -0.21, P = .01; BOP: rs = -0.21, P = .01; SB: rs = 0.05, P = .53). No statistically significant correlations were found between the clinical parameters evaluated and the sex or the dental arch treated (maxilla vs mandible). In contrast, the correlation between periodontal parameters and years elapsed since surgery (follow-up) was significant. CONCLUSIONS: The present research suggests that in implant-supported fixed partial rehabilitations, dental implants with greater plaque accumulation are more likely to present augmented probing depth, peri-implant inflammation, and bone loss, although the correlation is statistically very weak. Patient age and time of follow-up also significantly affected peri-implant health parameters.


Subject(s)
Alveolar Bone Loss , Dental Plaque Index , Dental Prosthesis, Implant-Supported , Periodontal Index , Humans , Male , Female , Middle Aged , Alveolar Bone Loss/etiology , Aged , Adult , Denture, Partial, Fixed , Peri-Implantitis/etiology , Dental Implants
6.
Head Face Med ; 20(1): 24, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627712

ABSTRACT

OBJECTIVES: A randomized controlled clinical trial of dental implants was conducted to compare the clinical properties of a novel electrochemically deposited calcium phosphate coating to those of a common marketed surface treatment. MATERIAL AND METHODS: Forty implants of the same brand and type were placed in 20 fully edentulous participants requiring mandibular implantation. The two study groups were defined by the surface treatment of the implants. 20 implants in the control group were coated via a commercial electrochemical surface treatment that forms a mixture of brushite and hydroxyapatite, while the remaining 20 in the test group were coated with a novel electrochemical Smart Bioactive Trabecular Coating (SBTC®). A split-mouth design was employed, with each participants receiving one control implant in one mandibular side and a test implant in the other. To mitigate potential operator-handedness bias, control and test implants were randomly assigned to mandibular sides. All cases underwent digital planning, implant placement with a static surgical guide, and participants received locator-anchored full-arch dentures. The primary outcome was implant stability (measured using Osstell ISQ) assessed at insertion, loading, and then 3 months, 9 months, and 2 years post-insertion. The secondary outcome was bone level change (in millimeters) over the 2-year observation period. Oral health-related quality of life (OHRQL) was monitored using the OHIP-14 questionnaire. Complications and adverse events were recorded. RESULTS: Successful osseointegration and implant stability were achieved in all cases, allowing loading. ISQ values steadily increased throughout the observation period. While no significant differences were observed between the SBTC® and control coatings, the test group exhibited a higher ISQ gain. Bone resorption was somewhat lower in the SBTC® but not significantly so. Patients' OHRQL significantly improved after denture delivery and remained stable throughout the follow-up. No complications or adverse events were observed. CONCLUSIONS: Based on the study results, we conclude that the new surface treatment is a safe alternative to the widely used control surface, demonstrating similar osseointegrative properties and time-dependent bone level changes. Further research may explore the broader implications of these findings. TRIAL REGISTRATION: The study is registered on clinicaltrials.gov under the identifier ID: NCT06034171.


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Dental Implantation, Endosseous/methods , Quality of Life , Osseointegration , Treatment Outcome , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis Design
7.
Trials ; 25(1): 267, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627819

ABSTRACT

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Subject(s)
Dental Implants , Jaw, Edentulous , Humans , Aged , Middle Aged , Denture, Overlay , Workflow , Mandible/surgery , Patient Satisfaction , Printing, Three-Dimensional , Dental Prosthesis, Implant-Supported , Randomized Controlled Trials as Topic
8.
Shanghai Kou Qiang Yi Xue ; 33(1): 90-96, 2024 Feb.
Article in Chinese | MEDLINE | ID: mdl-38583032

ABSTRACT

PURPOSE: To observe the long-term clinical effect of implants retained complete overdentures with Locator attachments. METHODS: A total of 48 patients with edentulous jaws treated with implants retained complete overdentures with Locator attachments were selected from the Outpatient Department of Peking University School and Hospital of Stomatology from 2016 to 2017. Among them, 21 patients underwent double-maxillary complete overdentures restoration and 27 patients underwent single-maxillary restoration. A total of 230 implants were implanted. The clinical observation indicators included the implant survival rate, peri-implant mucosal bleeding on probing(BOP), the change in the vertical height of alveolar bone absorption around the implants, overdenture base fracture rate, artificial tooth fall off and fracture rate and other complications. The change of the locator attachment retention force of the implant-supported overdentures was evaluated. SPSS 13.0 software package was used for data analysis. RESULTS: During the five-years clinical observation period, 5 implants fell off, 1 narrow dimeter implant in the anterior zone was broken, and 12 implants were lost to follow-up. The implant survival rate was 97.25%. One year after the restoration therapy finished, peri-implant mucosal bleeding on probing (BOP+) was detected in 48 (21.4%) implants. The average BI was 0.21±0.42, which was higher in the anterior zone than that in the posterior zone. The vertical alveolar bone absorption height around the implants was (0.21±0.35) mm, 2 implants-supported complete overdenture bases were broken. After 5 years of restoration, 163(76.89%) implants had peri-implant mucosal bleeding on probing(BOP+). The average BI was 1.00±0.70, and the vertical alveolar bone absorption height around the implants was (0.58±0.85) mm. There was no significant difference between males and females. There was no significant difference in the peri-implant mucosal bleeding index and the alveolar bone vertical absorption height between the anterior zone and the posterior zone(P>0.05). The mean BI of peri-implant mucosa and the vertical absorption height of peri-implant alveolar bone were significantly different between the 1-year observation period and the 5-year observation period respectively(P<0.01). There were 17(26.15%) cases with overdenture bases fracture, and the fracture rate of artificial teeth was 16.92%. Most of them occurred in the midline area of the anterior zone and the location of the overdenture base on the locator attachments. The average first replacement time of the locator attachment nylon retainer washer was 34.2±10.3 months. CONCLUSIONS: Implants retained complete overdentures with Locator attachments are effective in long term clinical observation. Complications are mainly found in peri-implant mucosal bleeding on probing and vertical alveolar bone absorption, and tended to increase gradually over time. The fracture of the implant retains complete overdenture bases and the fall off or fracture of the artificial teeth are the second serious complications. Overdenture base with metal frame at the location of the Locator abutment and the midline of the anterior area should be strengthened, and narrow diameter implants should be avoided as far as possible in the anterior zone.


Subject(s)
Dental Implants , Jaw, Edentulous , Male , Female , Humans , Denture, Overlay , Dental Prosthesis, Implant-Supported/adverse effects , Denture Retention , Mandible/surgery , Dental Implants/adverse effects
10.
BMC Oral Health ; 24(1): 425, 2024 Apr 06.
Article in English | MEDLINE | ID: mdl-38582842

ABSTRACT

BACKGROUND: Clinical scenarios frequently present challenges when patients exhibit asymmetrical mandibular atrophy. The dilemma arises: should we adhere to the conventional All-on-4 technique, or should we contemplate placing vertically oriented implants on the side with sufficient bone mass? This study aims to employ three-dimensional finite element analysis to simulate and explore the biomechanical advantages of each approach. METHODS: A finite element model, derived from computed tomography (CT) data, was utilized to simulate the nonhomogeneous features of the mandible. Three configurations-All-on-4, All-on-5-v and All-on-5-o were studied. Vertical and oblique forces of 200 N were applied unilaterally, and vertical force of 100 N was applied anteriorly to simulate different masticatory mechanisms. The maximum von Mises stresses on the implant and framework were recorded, as well as the maximum equivalent strain in the peri-implant bone. RESULTS: The maximum stress values for all designs were located at the neck of the distal implant, and the maximum strains in the bone tissue were located around the distal implant. The All-on-5-o and All-on-5-v models exhibited reduced stresses and strains compared to All-on-4, highlighting the potential benefits of the additional implant. There were no considerable differences in stresses and strains between the All-on-5-o and All-on-5-v groups. CONCLUSIONS: With the presence of adequate bone volume on one side and severe atrophy of the contralateral bone, while the "All-on-4 concept" is a viable approach, vertical implant placement optimizes the transfer of forces between components and tissues.


Subject(s)
Dental Implants , Humans , Biomechanical Phenomena , Finite Element Analysis , Stress, Mechanical , Dental Stress Analysis/methods , Dental Prosthesis, Implant-Supported , Mandible/diagnostic imaging , Atrophy
13.
BMC Oral Health ; 24(1): 405, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38555452

ABSTRACT

OBJECTIVE: To assess stress distribution in peri-implant bone and attachments of mandibular overdentures retained by small diameter implants, and to explore the impact of implant distribution on denture stability. METHODS: Through three-dimensional Finite Element Analysis (3D FEA), four models were established: three models of a two mandibular implants retained overdenture (IOD) and one model of a conventional complete denture (CD). The three IOD models consisted of one with two implants in the bilateral canine area, another with implants in the bilateral lateral incisor area, and the third with one implant in the canine area, and another in the lateral incisor area. Three types of loads were applied on the overdenture for each model: a 100 N vertical load and a inclined load on the left first molar, and a100N vertical load on the lower incisors. The stress distribution in the peri-implant bone, attachments, and the biomechanical behaviors of the overdentures were analyzed. RESULTS: Despite different distribution of implants, the maximum stress values in peri-implant bone remained within the physiological threshold for all models across three loading conditions. The dispersed implant distribution design (implant in the canine area) exhibited the highest maximum stress in peri-implant bone (822.8 µe) and the attachments (275 MPa) among the three IOD models. The CD model demonstrated highest peak pressure on mucosa under three loading conditions (0.8188 Mpa). The contact area between the denture and mucosa of the CD model was smaller than that in the IOD models under molar loading, yet it was larger in the CD model compared to the IOD model under anterior loading. However, the contact area between the denture and mucosa under anterior loading in all models was significantly smaller than those under molar loading. The IOD in all three models exhibited significantly less rotational movement than the complete denture. Different implant positions had minimal impact on the rotational movement of the IOD. CONCLUSION: IOD with implants in canine area exhibited the highest maximum stress in the peri-implant bone and attachments, and demonstrated increased rotational movement. The maximum principal stress was concentrated around the neck of the small diameter one-piece implant, rather than in the abutment. An overdenture retained by two implants showed better stability than a complete denture.


Subject(s)
Dental Implants , Humans , Denture, Overlay , Finite Element Analysis , Denture, Complete , Mandible , Dental Prosthesis, Implant-Supported , Dental Stress Analysis/methods , Denture Retention
14.
J Dent ; 144: 104935, 2024 May.
Article in English | MEDLINE | ID: mdl-38499282

ABSTRACT

OBJECTIVES: The recently introduced Implant Disease Risk Assessment (IDRA) identifies a restoration margin-alveolar bone crest (RM-AC) distance of less than 1.5 mm as a key risk factor for peri­implant disease among eight major risk factors. This study evaluated the impact of the RM-AC distance on marginal bone loss (MBL) through radiographic analysis. METHODS: This retrospective cross-sectional study included 77 partially edentulous patients (39 females and 38 males, aged 22 to 76 years) with 202 platform-switched conical connection implants, cement-retained, implant-supported fixed restorations, and bone-level implants placed between 2016 and 2021. Dental implants were followed for least 6 to 36 months at follow up functional loading. Study participants were categorized into Group A (RM-AC distance ≤ 1.5 mm, n = 69) and Group B (RM-AC distance > 1.5 mm, n = 133). Twelve patients in Group B and five patients in Group A had no history of periodontal disease. The MBL was measured radiographically from the most coronal point of the implant shoulder to the alveolar bone, and the RM-AC distance was measured from the restoration margin to the alveolar crest. Multinomial logistic regression analysis was used for statistical evaluation. RESULTS: The incidence of MBL in Group A was statistically significant and 3.42 times higher than that in Group B. The rate of MBL in periodontitis Stage 4 was found to be 26.31 times higher than that in periodontitis Stage 2. The incidence of MBL was 6.097 and 5.02 times higher with increasing implant diameter and length, respectively. CONCLUSION: This study conclusively demonstrates that RM-AC distance ≤ 1.5 significantly increases the risk of MBL, particularly in patients with a history of periodontal disease. CLINICAL SIGNIFICANCE: This study highlights the critical role of maintaining an RM-AC distance greater than 1.5 mm in the prevention of MBL, particularly in patients with a history of periodontal disease. Since implant diameter and length have a significant impact on the risk of MBL, it emphasizes that implant demographics should also be carefully evaluated.


Subject(s)
Alveolar Bone Loss , Alveolar Process , Dental Implants , Humans , Male , Female , Middle Aged , Retrospective Studies , Adult , Alveolar Bone Loss/diagnostic imaging , Alveolar Bone Loss/etiology , Aged , Cross-Sectional Studies , Dental Implants/adverse effects , Alveolar Process/diagnostic imaging , Dental Prosthesis, Implant-Supported/adverse effects , Jaw, Edentulous, Partially/diagnostic imaging , Young Adult , Dental Implantation, Endosseous/adverse effects , Risk Factors
15.
BMC Oral Health ; 24(1): 379, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38519932

ABSTRACT

INTRODUCTION: Over the years, implant therapy has been a commonly used treatment option for individuals who are partially or totally edentulous, with a long-term success rate of over 90%. With significant advancements in biomaterials and technology, implant dentistry can now conduct prosthetic rehabilitations in the majority of patients catering to all types of needs. However, in order to meet the demands of a patient base that is always growing, new trends in implantology are emerging in recent years that are focused on minimally invasive surgery and financial sustainability. In certain clinical scenarios, connecting teeth and implants to support fixed partial prosthesis (FPPs) may be a predictable and workable course of treatment. MATERIALS AND METHODS: 22 patients were selected for this study who had tooth and implant supported prosthesis placed as a final restoration. Out of these 22 patients; 12 were male and 10 were female patients. Implants were placed following proper protocol and if grafting procedures were required they were carried out. A second stage surgical procedure was carried out and delayed loading protocols were followed. The statistical analysis was done using the IBM SPSS 24.0, Chicago, USA. The survival of the implants and teeth were measured by the Kaplan Meier survival scale. Bone loss was assessed at baseline(upon loading), 12 months and 24 months. RESULTS: The implant survival rate was measured at 6 months, 12 months, 18 months and 24 months. At 24 months, one implant showed failure, so the survival rate of the implants were 95.4%. Bone loss of 1 mm was seen around one implant at 12 months. Bone loss of 1 and 2 mm was present around two implants and one implant respectively at 24 months. CONCLUSION: From the results of this study, we can conclude that tooth implant supported prosthesis show very good survival when used in rehabilitation cases.


Subject(s)
Alveolar Bone Loss , Dental Implants , Immediate Dental Implant Loading , Humans , Male , Female , Dental Implants/adverse effects , Follow-Up Studies , Dental Implantation, Endosseous/methods , Dental Implantation , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Treatment Outcome , Dental Prosthesis Design , Alveolar Bone Loss/etiology
16.
J Dent ; 143: 104903, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38437977

ABSTRACT

OBJECTIVE: To evaluate the clinical outcome of different designs of zirconia dental implants. DATA: This systematic review adhered to the PRISMA checklist and followed the PICO framework. The protocol is registered in PROSPERO (CRD42022337228). SOURCES: The search was conducted in March 2023 through four databases (PubMed, Web of Science, Cochrane Library, and Google Scholar) along with a search of references in the related reviews. Three authors reviewed on title, and abstract level and analysed the risk of bias, and all authors reviewed on a full-text level. STUDY SELECTION: Clinical studies excluding case reports for patients treated with different designs of zirconia dental implants were included. From a total of 2728 titles, 71 full-text studies were screened, and 27 studies were included to assess the risk of bias (ROBINS-I tool) and data extraction. After quality assessment, four studies were included, and the remaining 23 excluded studies were narratively described. RESULT: The included prospective studies with moderate risk of bias reported success and survival rates of one-piece implants that ranged between 95 and 98.4 % with no difference between different lengths and diameters. The acid-etched roughened surface showed higher clinical outcomes compared to other surface roughness designs. CONCLUSION: Promising 5-year clinical outcomes were found for one-piece zirconia implants with no difference between different diameters and lengths. Concerning surface roughness, better outcomes were found when using the acid-etched implant surface. However, due to the limited available studies, further high-quality clinical studies comparing zirconia one-piece and two-piece implants with different diameters, lengths, and surface roughness are needed. CLINICAL SIGNIFICANCE: Based on this systematic review, under suitable clinical situations, the one-piece zirconia implants with diameters of 4.0 mm, 4.5 mm, or 5.5 mm and lengths of 8 mm, 10 mm, 12 mm, or 14 mm have similar promising clinical outcomes. Additionally, the acid-etched roughened implant surface may be preferable.


Subject(s)
Dental Implants , Humans , Dental Materials/therapeutic use , Prospective Studies , Dental Restoration Failure , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Zirconium/therapeutic use
17.
J Contemp Dent Pract ; 25(2): 141-147, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38514411

ABSTRACT

AIM: To compare between the rehabilitation of atrophied maxilla with fixed prosthesis using two posterior zygomatic implants and two conventional anterior implants or four implants inserted according to the all-on-four concept regarding the patient quality of life and satisfaction after one year of prosthesis insertion. MATERIALS AND METHODS: Thirty-six patients with atrophic edentulous maxillae were randomized into two groups: Group I (rehabilitated with fixed prostheses supported by two zygomatic and two conventional implants in the anterior region) and group II (fixed prostheses on four implants in the anterior region following an all-on-four concept). One year after the placement of the definitive prostheses, patients completed oral health impact profile-14 and satisfaction questionnaires. RESULTS: All patients were satisfied regarding retention, stability, occlusion, comfort, cleaning, speaking, chewing, bolus quality, appearance, handling, prosthesis apart, and embarrassing, with no significant significance between two groups except satisfaction with surgical procedures and healing period. CONCLUSIONS: Using two distally tilted zygomatic implants or all-on-four concept to rehabilitate atrophied maxilla by fixed detachable prosthesis could be considered a promising functional and esthetic treatment option regarding the patient satisfaction. CLINICAL SIGNIFICANCE: Traditionally, treatment of maxillary atrophied ridges was done by bone grafting or sinus-lifting techniques; however, using all-on-four concept or zygomatic implants was a successful treatment as it has high success rates and highly satisfied by the patients. How to cite this article: Nagib MA, Ibrahim AM, Abdel-Rahman FH, et al. Evaluation of Quality of Life and Satisfaction with Fixed Prostheses on Zygomatic Implants vs All-on-Four Concept: A Randomized Clinical Study. J Contemp Dent Pract 2024;25(2):141-147.


Subject(s)
Dental Implants , Jaw, Edentulous , Humans , Quality of Life , Esthetics, Dental , Patient Satisfaction , Dental Prosthesis, Implant-Supported , Maxilla/surgery , Dental Implantation, Endosseous/methods , Jaw, Edentulous/surgery , Jaw, Edentulous/rehabilitation , Follow-Up Studies , Treatment Outcome
18.
Int J Prosthodont ; 37(1): 49-58, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38381984

ABSTRACT

PURPOSE: To compare the biomechanical responses of a normal mandible to an osteoporotic mandible with two-implant-supported magnetic attachments. MATERIALS AND METHODS: A 3D finite-element model of a two-implant-supported mandibular overdenture with magnetic attachments was developed, and normal and osteoporotic bone samples were prepared. Four types of load were applied to the overdenture in each model: 100 N vertical and oblique loads on the right first molar, and a 100 N vertical load on the right canine and incisors. Biomechanical behaviors of the peri-implant bone, implant, and mucosa were recorded. Maximum equivalent stresses and elastic strains were analyzed. RESULTS: Equivalent elastic strain in osteoporotic cortical and cancellous bone was 9% to 71% and was 142% and 207% greater than in normal cortical bone, respectively. Equivalent elastic strain in the first molar oblique loading condition was 101% to 190% greater than in the first molar vertical loading condition. CONCLUSIONS: Osteoporotic cancellous bone was weaker and less resistant to deformation than normal bone, and oblique loading was more harmful than vertical loading.


Subject(s)
Dental Implants , Denture, Overlay , Finite Element Analysis , Dental Stress Analysis , Dental Prosthesis, Implant-Supported , Mandible , Magnetic Phenomena , Stress, Mechanical
19.
J Oral Implantol ; 50(1): 50-64, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38329841

ABSTRACT

The choice of a splinted or nonsplinted implant-supported prosthesis should be based on solid scientific evidence that considers the conditions and needs of each patient. This review elaborates on the factors that directly influence clinical decisions between splinted or nonsplinted dental implants. Digital and manual searches of the published literature were conducted to identify studies that examined splinted prostheses (SPs) and nonsplinted prostheses (NSPs). The search terms used, alone or in combination, were "splinting prosthesis," "nonsplinting prosthesis," "prosthetic design," "stress distribution in dental implant," "implant loading," "implant occlusion," and "crestal bone resorption." Ninety-four studies were selected to compare and address the details emphasized in this study. Thirty-four reported articles were not directly related to restoration design but were reviewed to better understand the influence of mechanical risk factors, finite element analysis limits, and criteria for implant survival and treatment success. There are advantages and disadvantages of splinting implants together. NSPs are the ideal choice because they resemble natural teeth. Splinting a restored implant will cause the implant to appear as part of one unit and is indicated in more compromised situations, unfavorable conditions, or when pontic spaces and cantilevers are needed in implant prostheses.


Subject(s)
Dental Implants , Humans , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Treatment Outcome , Splints
20.
Clin Oral Implants Res ; 35(4): 419-426, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38329172

ABSTRACT

OBJECTIVES: To simulate the replacement of a premolar with an implant-supported cantilever fixed dental prosthesis (ICFDP) and how the fracture load is affected by implant type, positioning within the zirconia blank, and aging protocol. MATERIALS AND METHODS: Seventy-two ICFDPs were designed either within the enamel- or dentin layer of a 4Y-PSZ blank for bone-level and tissue-level titanium-zirconium implants. Fracture load was obtained on the cantilever at baseline (no aging) or after aging in a chewing simulator with the load applied within the implant axis (axial aging) or on the cantilever (12 groups with n = 6). A three-way ANOVA was applied (α = .05). RESULTS: A three-way ANOVA revealed a significant effect on fracture load values of implant type (p = .006) and aging (p < .001) but not for the position within the zirconia blank (p = .847). Fracture load values significantly increased from baseline bone level (608 ± 118 N) and tissue level (880 ± 293 N) when the implants were aged axially, with higher values for tissue level (1065 ± 182 N) than bone level (797 ± 113 N) (p < .001). However, when the force was applied to the cantilever, fracture load values decreased significantly for tissue-level (493 ± 70 N), while values for bone-level implants remained stable (690 ± 135 N). CONCLUSIONS: For ICFDPs, the use of bone-level implants is reasonable as catastrophic failures are likely to be restricted to the restoration, whereas with tissue-level implants, the transmucosal portion of the implant is susceptible to deformation, making repair more difficult.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Zirconium , Dental Restoration Failure , Materials Testing